Full Auto Ref R-F10
- Beyond Auto-Alignment -
-
Easier, more comfortable operation
The R-F10 replaces the conventional joystick with a trackball and roller
tandem that eases hand movement during manual alignment. And, once the
examinee's pupil is visible in the monitor, you just press the start button
to begin - and complete - measurements of refraction and keratometry.
-
More efficient exam procedures
From the first part of the process to the last, both instruments simply do
things better. Its measurement head covers an exceptional wide area, thus
speeding up the auto-alignment process, and even the built-in printer
delivers your printout faster than ever.
-
Increased measurement reliability
By simplifying operation, Canon's fully automated measurement technology,
takes on a greater share of the workload and increases the reliability of
measurement data. What's more, the unit's monitor employs a deep focal
point, which makes it easier for you to tell whether an examinee's eyelashes
are obstructing measurement.
-
Motorized chin rest
A motorized chin rest offers easy adjustment of the unit when beginning the
eye examination.
-
Ergonomic centralized control keys
The layout of the operation panel makes the unit easy to use from either a
seated or standing position. Furthermore, control keys for each of the
unit's main functions are grouped together for your convenience.
Refractometry
Sphere (SPH) |
-30 to + 22D when VD is set to 12mm |
Cylinder (CYL) |
0 to +/-10D |
Axis (AX) |
1 to 180 degree |
Pupil distance (PD) |
Max 85mm (increments: 1mm) |
Vertex distance (VD) |
0/12/13.5mm |
Minimum pupil size |
2.5mm diameter |
Power saving system
Available
Memory
Measurement values |
10 for each eye |
Built-in printer |
Thermal line printer |
Dimensions |
Approx 11 x 20.5 x 18.5 inches |
Auto Ref-Keratometer RK-F1
- Beyond Auto-Alignment -
-
Easier, more comfortable operation
The RK-F1 replaces the conventional joystick with a trackball and roller
tandem that eases hand movement during manual alignment. And, once the
examinee's pupil is visible in the monitor, you just press the start button
to begin - and complete - measurements of refraction and keratometry.
-
More efficient exam procedures
From the first part of the process to the last, both instruments simply do
things better. Its measurement head covers an exceptional wide area, thus
speeding up the auto-alignment process, and even the built-in printer
delivers your printout faster than ever.
-
Increased measurement reliability
By simplifying operation, Canon's fully automated measurement technology,
takes on a greater share of the workload and increases the reliability of
measurement data. What's more, the unit's monitor employs a deep focal
point, which makes it easier for you to tell whether an examinee's eyelashes
are obstructing measurement.
-
Widest measurement range
For refraction, its dioptric measurement range of -30D to +22D is among the
widest available, which allows you to better examine strong myopia and other
abnormalities. And for keratometry, the radius of curvature extends from
5.5mm to 10.0mm.
-
Corneal periphery measurement
The RK-F1 can be used to make a series of measurements at a 30 degrees angle
from the eye's center, along the attentive meridians.
-
Retroillumination
Through retroillumination, the RK-F1 brings you an extremely detailed view
of the eye's that's particularly useful for identifying cataracts, vitreous
opacity, scars, and other serious eye problems.
-
Diameter measurement
Diameter measurements of the cornea or pupil, or of a contact lens being
worn during the eye examination, are easily to get with the RK-F1.
-
Motorized chin rest
A motorized chin rest offers easy adjustment of the unit when beginning the
eye examination.
-
Ergonomic centralized control keys
The layout of the operation panel makes the unit easy to use from either a
seated or standing position. Furthermore, control keys for each of the
unit's main functions are grouped together for your convenience.
Refractometry
Sphere (SPH) |
-30 to + 22D when VD is set to 12mm |
Cylinder (CYL) |
0 to +/-10D |
Axis (AX) |
1 to 180 degree |
Pupil distance (PD) |
Max 85mm (increments: 1mm) |
Vertex distance (VD) |
0/12/13.5mm |
Minimum pupil size |
2.5mm diameter |
Keratometry |
|
Radius of curvature |
5.5 to 10mm |
Corneal power |
33.75 to 61.25D when cornea equivalent refractive index is 1.3375 |
Axis |
1 to 180 degree |
Corneal periphery |
Measurement area: 30 degrees |
Corneal diameter measurement |
|
Corneal diameter |
2.0 to 16.0mm |
Power saving system
Available
Memory
Measurement values |
10 for each eye |
Built-in printer |
Thermal line printer |
Dimensions |
Approx 11 x 20.5 x 18.5 inches |
| Objective
Refractometer Mode |
|
| Sphere: |
-25D
to +22D (0.12D/0.25D) |
Cylinder: |
0D
to ±10D (0.12D/0.25D) |
Axis: |
0°
to 180° (in 1° or 5° steps) |
Minimum
Pupil Diameter: |
Ø2.0mm |
Target
Fixation: |
Auto
fog system |
|
|
Corneal
Curvature Mode |
|
Corneal
Curvature Radius: |
5.00
to 10.00mm (0.01mm) |
Refraction
Index: |
1.3375 |
| Corneal
Refraction: |
67.5D
to 33.75D (0.12D/0.25D) |
| Corneal
Astigmatism: |
0
to ±10D (0.12D/0.25D) |
| Corneal
Astigmatism Axial Angle: |
0°
to 180° (in 1° or 5° steps) |
| Measuring
Area: |
3mm
with 7.7mm radius |
|
|
| Others |
|
| PD
Measurement Range: |
85mm
max. in 1mm steps |
| Measurement
Start: |
Auto
Start/Manual (selectable) |
| Measurement
Display: |
Color
LCD monitor |
| Measurement
Recording: |
Built-in
printer (up to 10 measurements of each eye can be stored in memory) |
| Alignment: |
5"
LCD |
| Vertex
Distance: |
0,
12.0 and 13.75mm (selectable) |
| Energy
Saving: |
Automatic
Power Saver Mode when left unused for 10 minutes |
| Power
Supply: |
100-120,
220-240V AC, 50/60 Hz, 75VA |
| Output: |
RS-232C
/ USB 1.1 |
| Dimensions: |
275(W)
x 475(D) x 450(H)mm |
| Weight: |
20kg |

| Objective
Refractometer Mode: |
|
| Sphere: |
-25D
to +22D (0.12D/0.25D) |
Cylinder: |
0D
to ±10D (0.12D/0.25D) |
| Axis: |
0°
to 180° (in 1° or 5° steps) |
Minimum
Pupil Diameter: |
Ø2.0mm |
| Target
Fixation: |
Auto
fog system |
|
|
| Others: |
|
| PD
Measurement Range: |
85mm
max. in 1mm steps |
| Measurement
Start: |
Manual |
| Measurement
Display: |
Color
LCD monitor |
| Measurement
Recording: |
Built-in
printer (up to 10 measurements of each eye can be stored in memory) |
| Alignment: |
5"
LCD |
| Vertex
Distance: |
0,
12.0 and 13.75mm (selectable) |
| Energy
Saving: |
Automatic
Power Saver Mode when left unused for 10 minutes |
| Power
Supply: |
100-120V,
220-240V AC, 50/60 Hz, 60VA |
| Output: |
RS-232C
/ USB 1.1 |
| Dimensions: |
275(W)
x 475(D) x 450(H)mm |
| Weight: |
20kg |

TECHNICAL
SPECIFICATIONS
|
Objective
Refractometer Mode
|
|
Sphere:
|
-25
to +22D in 0.25D step (0.12D step available)
|
Cylinder:
|
0 to
± 8D in step 0.25D (0.12D step available)
|
Axis:
|
1°
to 180° in 1° step
|
Minimal Pupil Diameter:
|
2.0mm
|
Method of Relaxation:
|
Automatic
Fogging
|
Charts for Objective Testing:
|
Picture
|
|
|
Corneal Cirvature
Mode
|
|
Corneal Curvature Radius:
|
5.00mm
~ 10.00mm, in 0.01mm step
|
Corneal Refraction:
|
67.5D
~ 33.75D
|
Refraction Index:
|
1.3375
|
Corneal Astigmatism:
|
0D ~ ± 10D
|
Corneal Astigmatism Axial Angle:
|
1° ~ 180° , 1° step
|
Measuring Area:
|
3mm with 7.7mm radius
|
|
|
Corneal Mapping
Mode
|
|
Measuring Area:
|
1.5mm to 10mm (R=7.7)
|
Image Display:
|
TV Monitor
|
Image Output:
|
BNC
|
Data Output:
|
RS-232C
|
|
|
Other General
Specifications
|
|
PD Measurement Range:
|
85mm max. in 1mm step
|
Measuring Start:
|
Auto Alignment / Auto Start / Manual Mode
|
Corneal Diameter Measurement:
|
Yes
|
Pupil Diameter:
|
Range: 2~13mm / Step: 0.25mm
|
Measurement Recording:
|
Built-in printer (up to 10 measurements of
each eye)
|
Alignment:
|
Screen Display
|
Vertex Distance:
|
0, 12.0 and 13.75mm (selectable)
|
Energy Saving:
|
Automatically turns off when left unused for
10 minutes
|
IOL:
|
Special IOL switch to adjust to
circumstances of IOL wearers
|
Power Supply:
|
100, 120, 220, 240V
|
Weight:
|
19kg
|
Dimensions:
|
275 (W) X 475 (D) X 450 (H) mm
|
|