Applanation Tonometers are still the most widely used
instruments to measure inter-ocular pressure.
The advantages of the "Goldmann" method are
considerable. The measurement can be carried out on the patient sitting at the
slit lamp in conjunction with other routine microscopic examinations. The
accuracy of the measurement is extremely high. The average deviation in any one
single examination does not exceed +/- 0.5. mm HG. Furthermore, repeated
measuring procedures do not reduce the ocular pressure, as no massing effect
occurs. Last but not least, there are no standardization or calibration
difficulties.
R900
Applanation Tonometer
The R900 Applanation Tonometer is produced for those who prefer the
tonometer to remain permanently on the slit lamp. It is mounted on a pivot on
the microscope and for examination is swung forward in front of the microscope.
The applanation surface is to be examined in a monocular manner through the left
ocular.
Catalog #0900-2101
For use with these Slit Lamps
Haag-Streit BM900
CSO SL 990 Series
Marco 2B, 5 & G5
Reichert XCEL 300, 400 & 700
Topcon 1E, 3E, 7e & 8Z
BQ Applanation Tonometer
The BQ Applanation Tonometer is especially made to fit the BQ
stereo-microscope. Apart from the working position, there are also two resting
positions. For perfect tonometric examination of the left and right eye the tonometer is swung in front of the microscope and the
illumination unit moved from the left to touch the bracket of the tonometer. In
this position, the left and right eyes of the patient can be examined without
difficulty (to 60°).
Catalog #09004.4
For use with
Haag-Streit BQ900, BP900 & BX900 Slit Lamps
BC900
/ BD900
Applanation Tonometer
The BC900 / BD900 Slit Lamp accepts the traditional Goldmann Tonometer (a blue filter
is built-in to the Slit Lamp) which mounts onto the microscope and can be
swiveled into position when required.
Catalog #0900.2106
For use with
Haag-Streit BC900 and BD900 Slit Lamps
870
Applanation Tonometer
The Applanation Tonometer 870 is to be mounted over the microscope of the
slit lamp. The feeler arm protrudes from above into the path of the microscope
and the illumination unit. The Tonometer is ready four use with a single swing
movement of the feeler arm.
Catalog #0870.0002
For use with these Slit Lamps
CSO 980 Series
Marco G2 & G4
Reichert XCEL 200
Topcon SL-2ED & SL-4ED
|
|
Convenient item for daily clinical practice
|
Key Features:
- Compact
and light-weight, well balanced and easy to handle by
single hand
-
Unique one-spring mechanism assures correct reading
regardless of patient posture
-
Built-in illumination permits you to use the instrument
regardless of the illuminating condition of
consultation room
-
Direct reading type precision dial requires no conversion
table to change the readings.
-
Accessories such as adjustable head rest and interchangeable
eyepiece provide most suitable condition for
measurement
|
|
|

Catalog # 23-0635
Description: Tono-Pen XL Tonometer Starter Pack with Carrying Case.
1 box of Ocu-Film Tip Covers. 1 pkg. Ocu-Cel XL Batteries.
Instructional Video and Manual.
Perkins
Hand Held Applanation Tonometer
The Perkins has been established for well over 20 years as a
"world standard" for hand held applanation tonometers.
Goldmann Standards Based on Goldmann
principles and utilizing the original Goldmann or Tonosafe disposable
prisms, the Perkins combines proven technology with the flexibility of a
hand held instrument.
Portable Post-operative, bed-ridden, and
pediatric patients have always been difficult to examine by traditional
applanation tonometry methods. The Perkins was designed specifically
with these patients in mind.
Versatile and Accurate Tonometry In busy
clinics and practices with limited resources, there are times when a
hand-held applanation tonometer is more convenient and cost effective
for
examining multiple patients.
Combined with convenience and versatility, the Perkins offers proven
accuracy and brilliant visibility. Precision counter-balanced movements
allow reading to be taken with the patient in any position. The
illumination system provides superior fluorescein, greatly enhancing the
familiar "semi-circles" which are vital to attaining accurate results.
Every Perkins Tonometer is calibrated to the highest quality standards
and comes with a signed and dated Certificate of Accuracy.
Examine at Arms Length The optional Perkins
Examination Telescope (P.E.T.) allows magnified viewing of the
fluorescein "semi-circles" at arms length, making examinations more
comfortable for both the ophthalmic professional and the patient. And
because the P.E.T. also makes it possible for two people to view
simultaneously, it can be used as an effective teaching aid.
Accessories The Perkins Tonometer comes
standard with a lightweight, compact carrying case, Goldmann Prism and
battery operated handle taking four AA size batteries. Accessories
include a rechargeable handle and recharging unit and Tonosafe
disposable prisms. |
The
results of Goldmann Applanation tonometry vs
Pulsair
Non Contact Tonometry are in....
and
it's good news for helping you detect Glaucoma Suspects.
|
|
EASY
TO USE · ACCURATE · GENTLE · MOBILE · AFFORDABLE |
 |


 |
EASY
TO USE
Easy
as ~ 1 ~ 2 ~ 3
1 ~
Seeing eye optics
Allows easy alignment of the patient's eye
with the instrument.
2 ~
Green tracking diodes
Gives an easy indicator to ensure the
optimal position prior to automatic
activation .
3 ~
Bow Tie Easy Activation
Centralize the focused bow tie for
automatic activation.
Based
on over one hundred clinical evaluations of Puslair EasyEye the maximum
training time for non-technical personal was 3 minutes. |


GENTLE
Pulsair
Easyeye is streamlined, quiet and
now, with constant puff monitoring technology. There's no
discomfort, just a gentle puff of air. You can prove how gentle
the puff is with a demonstration on the patient's hand before you
start. With the new soft puff they will feel much more at
ease, which will significantly reduce the squeezing effect and
give you more consistent readings. |
AFFORDABLE |
ACCURATE
Pulsair
EasyEye is the only handheld non contract tonometer with over 17 years
of clinical experience.
A
recently published study has established the accuracy of Pulsair in
relation to applanation tonometry.*
The
same study has confirmed that Pulsair could replace applanation
tonometry or the two methods could be interchangeable.
Based
on 150 eyes with an IOP range of 10mm Hg to 44mm Hg "Pulsair is as
accurate as Goldmann tonometry in the population studied and has
distinct advantages".

MOBILE
-
Pulsair is the only clinically proven handheld non
contact tonometer
you can use on all your
patients.
-
Lightweight
and portable, Pulsair Easyeye comes
with an
optional rechargeable battery, so that
moving between
your offices is easy. The unit comes
with an optional
carrying bag, to make light work of
transporting it
from place to place.
-
The
results of your readings will be automatically
printed,
this will include the mean measurements,
along with
the number of readings taken. All you
need to do is attach it your patients records.
|
-
With
the lowest priced Non Contact Tonometer on the market $4,995.00, Pulsair Easyeye
could possibly be the only tonometer you need.
-
Pulsair
Easyeye can be used on all disabled people. Tax benefits can be gained due to The
Americans with Disabilities Act. Contact your tax accountant for more information on The
Americans with Disabilities Tax Credit (Title 26, Internal Revenue code, Section 44).
*CLINICAL
COMPARISON OF THE KEELER PULSAIR WITH GOLDMANN APPLANATION TONOMETRY.
*SOURCE:
British Journal of Ophthalmology, November 2001, Vol 85, No 11, p. 1303-1304.
Comparison study conducted at the Dept of Ophthalmology, Addenbrookes Hospital
Trust, Cambridge, U.K Authors; V A Parker, J Heritage and N J C Sarkies.

Reichert introduced the first non-contact tonometer in 1972.
Overview
The AT555
utilizes a patented hands-free automatic alignment system, enabling any member
of your staff to take an accurate IOP measurement in seconds.
The operator simply slides the headrest to the left or right and invites the
patient to position their head against the comfortable headrest pad. The AT555
automatically detects which eye is being measured, takes the measurement, and
displays the results on the LCD screen. Measurement data can be easily printed
with the push of a button.
Reichert introduced the first non-contact tonometer in 1972.

Overview
Totally cordless,
the lightweight PT100 has a long-life rechargeable battery, so it can be used
on all patients wherever you need it.
Featuring a user-friendly icon-based operating system and an easy to read
backlit LCD, the PT100 can display up to 3 IOP measurements and an average for
each eye.
In addition, every system includes a wireless printer and a custom designed
carrying case. The Reichert PT100 puts fast, easy, and accurate non-contact
tonometry in the palm of your hand.
key features
download brochures
download articles and papers
Reichert’s new ATP Auto Non-Contact Tonometer
/ Pachymeter is the first fully integrated tonometer / pachymeter, combining
the measurement of IOP and CCT into one instrument.Designed in response to numerous clinical
studies that have shown the importance of measuring central corneal thickness
as well as intraocular pressure in the management of glaucoma patients, the
ATP instrument combines both functions and provides complete information on a
simple-to-read, color display.
|
|
|
|